Error Code Reference (exccode)
Overview
Every service state SiteRM Frontend reports (OK, WARNING, FAILED) now carries a stable, machine-readable numeric error code alongside the human-readable message. This lets dashboards, alerts, and scripts key off a fixed number instead of parsing free-text log lines, which can change wording over time.
Codes are permanent — once a number is assigned, it is never reused or reassigned to a different error.
Where you’ll see these:
- Database:
servicestates.exccode(single int, the primary code for that report) andservicestates.exccodes(JSON list — aWARNINGreport can legitimately batch more than one distinct cause into the same cycle, e.g. an SNMP timeout and a stale VLAN both tripping in the same run). - REST API:
GET /api/{sitename}/servicestatesreturns both fields for every row. - Prometheus: the
siterm_error_eventsgauge (labels:servicename,hostname) reports the primary code only —0when the service state isOK, the negative code otherwise. It intentionally does not enumerate every code fromexccodesas separate label combinations, to avoid unbounded metric cardinality. - Frontend logs: the human-readable message that generated the code is always still logged in full; the code is metadata alongside it, not a replacement for it.
Code ranges
| Range | Meaning |
|---|---|
-1 … -99 |
A specific Python exception class was caught (see Exception codes) |
-100 |
Unknown / unclassified — the exception or condition has no code mapping yet |
-101 … -199 |
A named condition that isn’t a Python exception — an SNMP failure, a free-text Warnings.addWarning() category, etc. (see Warning / sentinel codes) |
Source of truth: exceptionCode() in SiteRMLibs/CustomExceptions.py.
Warning / sentinel codes
These are the codes you’re most likely to see day-to-day — they come from Warnings.addWarning() call sites across the Frontend and report through servicestates as a WARNING state. Each one already existed as a warning message before it had a code; several are also covered informally on the Common Issues page.
-101 — SNMP_TIMEOUT
[{host}]: Got SNMP Timeout Exception: {details}
Cause: SNMPMonitoring could not reach the switch’s SNMP agent in time.
Resolution: Check the switch is reachable and SNMP is enabled and responsive (community/version in snmp_monitoring config). Transient on a loaded switch; persistent if the switch or network path is down.
-102 — SNMP_UNKNOWN_OID
[{host}]: Got SNMP UnknownObjectID Exception for key {key}: {details}
Cause: The switch does not support the requested OID (vendor/firmware difference, or misconfigured MIB path).
Resolution: Verify the OID/MIB used for this device family and firmware version; adjust the SNMP monitoring config if the device genuinely doesn’t expose it.
-103 — ANSIBLE_UNREACHABLE
Reserved for a future Ansible-unreachable-host condition. Not yet emitted by any code path.
-104 — ANSIBLE_PLAYBOOK_FAILED
Reserved for a future Ansible-playbook-failure condition. Not yet emitted by any code path.
-105 — SERVICE_DEAD
Reserved for a future “service hasn’t reported in SERVICE_DEAD_TIMEOUT” condition. Not yet emitted by any code path — the UNKNOWN state computed in SNMPMonitoring.__getServiceStates() doesn’t carry this code today.
-106 — SERVICE_DOWN
Reserved for a future “service down beyond SERVICE_DOWN_TIMEOUT” condition. Not yet emitted by any code path.
-107 — VALIDATOR_SWITCH_NO_ANSIBLE_OUTPUT
Switch {switch} defined in configuration, but no output received from Ansible call.
Cause: The switch is listed under switch in the site config, but the Ansible run never returned data for it.
Resolution: Check Ansible connectivity/credentials for that switch, and confirm the switch name matches what Ansible reports.
-108 — VALIDATOR_PORT_NO_ANSIBLE_OUTPUT
Switch {switch} port {port} defined in configuration, but no output received from Ansible call.
Cause: The port is defined under that switch’s ports config, but Ansible didn’t return data for it specifically (the switch itself did respond).
Resolution: Confirm the port name/format matches what Ansible reports for this device family; see the relevant Network Device page.
-109 — VALIDATOR_HOST_LLDP_MISMATCH
Host {hostname} does not match lldp information. Host Info: {...}, Switch LLDP Info: {...}
Cause: The host’s reported MAC address doesn’t match what LLDP sees on the switch port it’s supposed to be connected to.
Resolution: Confirm the host is physically connected to the port SiteRM expects, and that the host’s agent interface/MAC config is correct.
-110 — LIVENESS_READINESS_DISABLED
Liveness check is disabled on Frontend. Please enable it to ensure proper operation.
Readiness check is disabled on Frontend. Please enable it to ensure proper operation.
Cause: The liveness or readiness check has been manually disabled on this Frontend (a siterm-liveness-disable / siterm-readiness-disable file exists under the temp dir).
Resolution: Remove the disable file once whatever required disabling the check is resolved — leaving it disabled long-term hides real failures from Kubernetes/monitoring.
-111 — DELTA_STATE_TRANSITION_ERROR
Message varies — it’s whatever error the delta state machine returned for the failing transition (committing, committed, activating, activated, remove, removed).
Cause: A delta failed to move to the expected next state.
Resolution: Check the Frontend’s DBWorker/PolicyService logs for the specific transition and underlying error; often a downstream provisioning or validation failure for that delta.
-112 — SWITCH_VLAN_RANGE_EXHAUSTED
VLAN Range for {switch}:{port} is not available or remaining vlans is empty.
Cause: All VLANs in the configured range for this switch port are currently allocated.
Resolution: This is a warning, not fatal — no new requests can be provisioned on this port until a VLAN frees up. See No Remaining VLANs on the Common Issues page.
-113 — NODE_VLAN_RANGE_EXHAUSTED
VLAN Range for {hostname}:{interface} is not available or remaining vlans is empty.
Cause: Same as -112, but for a host/agent interface rather than a switch port.
Resolution: Same as -112 — warning only; no new requests accepted on that interface until capacity frees up.
-114 — VLAN_MANUAL_CONFIG_MISMATCH
Vlan {vlan} is configured manually on {host}. It comes not from delta. Either deletion did not happen or was manually configured.
Cause: A VLAN inside the SENSE-managed range exists on the device/host but isn’t tracked by any active delta.
Resolution: See VLAN Manually Configured on the Common Issues page — usually a leftover from a failed deletion, or someone configured it by hand.
-115 — MODEL_UPDATE_LOOP_SUSPECTED
Model has updated more than 60 times. Please check LookupService/PolicyService for possible issues.
Cause: The topology model has been rebuilt far more often than expected, usually meaning something is flapping (a switch, an interface, or a delta) and causing LookUpService to recompute the model on every cycle.
Resolution: Check LookUpService/PolicyService logs around the time this fired for what keeps changing; a flapping link or a delta stuck retrying are the usual causes.
-116 — SWITCH_CHANNEL_MEMBER_DOWN
Channel member {member} of port {switch}{port} is not up. Line protocol: {...}, Oper status: {...}
Cause: One member link of a port channel/LAG is down while the channel itself is still being modeled.
Resolution: Investigate the specific member link — this doesn’t necessarily mean the whole channel is down, but a degraded member reduces available capacity.
-117 — SWITCH_PORT_NOT_SWITCHPORT
Port {switch}{port} not added into model. Its status not switchport. Ansible runner returned: {...}.
Cause: Ansible reports this port isn’t operating as a switchport, so it was excluded from the model. Common right after a device reboot or a config change that temporarily drops switchport mode.
Resolution: If the port should be a switchport, check its running config on the device. If this is expected (e.g. a routed port), no action needed — set allports for the switch to suppress this warning for ports intentionally excluded.
-118 — AGENT_HOST_PUBLISH_FAILED
Message combines whatever host-update/insert publish errors occurred, e.g.:
... Could not publish to SiteFE Frontend. Update to FE: Error: ... HTTP Code: ... Add tp FE: Error: ... HTTP Code: ...
Cause: The SiteRM Agent on a DTN could not publish its host info to the Frontend’s /api/{sitename}/hosts endpoint.
Resolution: Check network connectivity and certificate/auth validity between the Agent and the Frontend, and the Frontend’s REST logs for the corresponding request.
-119 — SWITCH_PORT_OPER_DOWN
Port {switch}{port} is enabled in SiteRM config but operstatus is '{operstatus}' (lineprotocol '{lineprotocol}'); excluded from the model. Expected connected/up.
Cause: A port (or port channel) explicitly listed under that switch’s ports config is a valid switchport but is not operationally up — its operstatus is something other than up/connected (e.g. notconnect, errdisabled, disabled, down, lowerLayerDown), or its lineprotocol is down. Unlike -116, this fires for the port itself, not just port-channel members, and covers a standalone access/trunk port or a whole port channel going down.
What SiteRM does: the port is left out of the published model for as long as it stays down, and this warning is raised so site admins still see it. Ports pulled in only via allports are dropped the same way but silently, without the warning. The check is vendor-agnostic (AristaEOS, Dell, Cisco NX, Junos, SONiC, Nokia SROS, FRR, FreeRTR all report a normalized operstatus); a device that does not report operstatus at all is not flagged or excluded.
Resolution: Investigate the port on the device — cable/optic, the far-end host or switch, or an errdisable condition (e.g. a config change or a loop that shut the port). The port returns to the model automatically on the next SiteRM refresh once operstatus is back to up/connected. If the port is intentionally down long-term, move it under ports_ignore (or remove it from ports) so the warning stops.
Exception codes
These come from a specific Python exception class being caught somewhere in the Frontend or Agent (policyService.getError(), Daemonizer.reporter(..., excType=...)). They’re lower-level than the warning codes above and generally indicate a request/processing failure rather than an operational/infrastructure condition.
| Code | Exception | Meaning |
|---|---|---|
| -1 | IOError |
Filesystem or I/O operation failed |
| -2 | KeyError |
Expected dictionary key was missing |
| -3 | AttributeError |
Code accessed a missing attribute — usually an unexpected None or malformed object |
| -4 | IndentationError |
Malformed Python source was executed/parsed (rare; usually a bad plugin/config file) |
| -5 | ValueError |
A value was the wrong type or out of the expected range |
| -6 | PluginException |
A switch/device plugin raised a general error |
| -7 | NameError |
Code referenced an undefined name |
| -8 | PluginFatalException |
A switch/device plugin raised an unrecoverable error |
| -9 | OverlapException |
A requested resource (e.g. VLAN, IP) overlaps with an existing allocation |
| -10 | NotFoundError |
A requested item was not found |
| -11 | BackgroundException |
A background task failed |
| -12 | ServiceWarning |
Generic/uncategorized warning — see Warning / sentinel codes for the specific categories this now normally resolves to instead |
| -13 | ConfigException |
Site or Frontend configuration is invalid or incomplete |
| -14 | WrongInputError |
Caller supplied invalid input |
| -15 | FailedToParseError |
Failed to parse an expected format (e.g. topology, request payload) |
| -16 | BadRequestError |
REST API request was malformed |
| -17 | ValidityFailure |
A value failed validation |
| -18 | NoOptionError |
Expected configuration option was missing |
| -19 | NoSectionError |
Expected configuration section was missing |
| -20 | WrongDeltaStatusTransition |
Delta state machine transition isn’t allowed from the current state |
| -21 | DeltaNotFound |
Referenced delta ID does not exist |
| -22 | ModelNotFound |
Referenced model ID does not exist |
| -23 | HostNotFound |
Referenced host is not known to the system |
| -24 | ExceededCapacity |
Requested capacity exceeds what the node can provide |
| -25 | ExceededLinkCapacity |
Requested capacity exceeds what the link can provide |
| -26 | ExceededSwitchCapacity |
Requested capacity exceeds what the switch can provide |
| -27 | DeltaKeyMissing |
A required key was missing from a delta |
| -28 | UnrecognizedDeltaOption |
A delta contained an option SiteRM doesn’t recognize |
| -29 | FailedInterfaceCommand |
A device interface command failed to execute |
| -30 | FailedRoutingCommand |
A device routing command failed to execute |
| -31 | TooManyArgumentalValues |
Too many values were supplied for an argument |
| -32 | NotSupportedArgument |
An unsupported argument value was supplied |
| -33 | ServiceNotReady |
A dependent service was not ready to handle the request |
| -34 | HTTPServerNotReady |
The HTTP server was not ready to accept requests |
| -35 | HTTPException |
Generic HTTP-layer exception |
| -36 | WrongIPAddress |
An IP address was invalid or malformed |
| -37 | OverSubscribeException |
A resource was oversubscribed beyond its allowed limit |
| -38 | FailedGetDataFromFE |
An Agent failed to retrieve expected data from the Frontend |
| -39 | SwitchException |
A switch communication error occurred |
| -40 | RequestWithoutCert |
A request arrived without a required client certificate |
| -41 | IssuesWithAuth |
Authentication or authorization failed |
| -42 | BadSyntax (rdflib) |
The RDF/Turtle/N3 topology could not be parsed |
-100 — Unknown: the exception or condition doesn’t have a code mapping yet. If you see this often for the same underlying cause, it’s worth opening an issue so it can get a proper code.